Revised: 11/13/2008 Provided links give access to illustrations and/or additional information. To return to this page use your browser back button. Crossover Connections
Using combination ring gaskets and combination bolts Certain nominal size API Spec 6A flanges, with different working pressures have:
These corresponding flanges may join together in a crossover connection without using an adapter. The connection make-up requires a combination ring gasket and combination bolts. Such a connection has the rated working pressure of the lowest pressure flange. To join 7-1/16" 3000 to 7-1/16" 5000 flanges utilize a R-45/R-46 combination ring gasket and 12, special 1-1/8" x 1-3/8" x 9-7/8" long combination bolts with 1, 1-1/8" and 1, 1-3/8" nut each. To join 9" 3000 to 9" 5000 flanges utilize a R-49/R-50 combination ring gasket and 12, special 1-3/8" x 1-5/8" x 11" long combination bolts with 1, 1-3/8" and 1, 1-5/8" nut each. The illustration below shows the configuration of an installed combination ring gasket and special combination bolts necessary to join the above identified flanges.
The illustration below shows the detail of a cross section of the combination ring gasket shape necessary to connect the above-identified flanges.
Using combination adapter ring gaskets 2-1/16" 3000 R-24 and 2-1/16" 5000 R-24 flanges have identical dimensions and connect without special provisions. Older 2-1/16" 3000 or 2-1/16" 5000 flanges with ring grooves to accommodate R-23 ring gaskets may connect to either 2-1/16" 3000 R-24 or 2-1/16" 5000 R-24 flanges with the use of R-23/R-24 special combination adapter ring gaskets and standard bolts. 2-9/16" 3000 R-27 and 2-9/16" 5000 R-27 flanges have identical dimensions and connect without special provision. Older 2-9/16" 3000 or 2-9/16" 5000 flanges with ring grooves to accommodate R-26 ring gaskets may connect to either 2-9/16" 3000 R-27 or 2-9/16" 5000 R-27 flanges with the use of R-26/R-27 special combination adapter ring gaskets and standard bolts. The illustration below shows a cross section of the special combination adapter ring gasket shape necessary to connect the above-identified flanges.
SMALLER PITCH
DIAMETER GASKET SURFACE
R-24 OR R-27
No rule establishes guidelines for any derating of these joined 2-1/16" or 2-9/16" flanges. Caution: Operators should take special care not to identify 3000 psi rated equipment with these R-23, R-24, R-26 and R-27 ring grooves as 5000 psi equipment based on flange measurement. For more information about joining flanges of unequal pressure and the uses of combination ring gaskets, see Double Drilled Flanges.
|
|||||||||||||||||||||||||
|
Information above, and in other
parts of this Web Site, may help persons who really seek to know. If you
have a question, and you think WOODCO USA may have the capacity to answer
it, please use our
Contact Us link and give us a
chance to help. WOODCO USA provides Web Site Tools for identification, estimating, and reference only. Do not use this information for manufacturing or inspection. Users of these tools should not use them as a substitute for professional engineering advice. Anyone making use of the information presented does so at his own risk and assumes any and all liability resulting from such use. FOR FURTHER INFORMATION, OR TO LEARN MORE ABOUT WOODCO USA PRODUCTS AND SERVICES, CONTACT: WOODCO USA
|